BOSCH Starter ZJS-B-001  CS1330  LRS01675    0-001-120-406 0-001-120-407 02T-903-024R 02Z-903-023C  32675  STR50263  12V/1.0KW  10  CCW  Audi, Volkswagen

Model NO.: CS1330 LRS01675 32675
OEM No.: 0-001-120-406, 0-001-120-407, 02T-903-024R
Cargo No.: 0
Woodauto No.: STR50263
Teeth and Rotation: 10    CCW
Application: BMW 525td 2.5L E39 1996-00
Trademark: ZJ
Transport Package: Neutral Packing
Origin: China
HS Code: 85114099
Model NO.: CS1330 LRS01675 32675
OEM No.: 0-001-120-406, 0-001-120-407, 02T-903-024R
Cargo No.: 0
Woodauto No.: STR50263
Teeth and Rotation: 10    CCW
Application: BMW 525td 2.5L E39 1996-00
Trademark: ZJ
Transport Package: Neutral Packing
Origin: China
HS Code: 85114099
 
Item OE Maker BOSCH Starter
Lester No. 32675
Power.: 12V/1.0KW
ZJ No. ZJS-B-001
Hc Parts CS1330
Lucas No. LRS01675
Cargo No.  
OEM  No. 0-001-120-406,0-001-120-407,02T-903-024R,02Z-903-023C
Woodauto No. STR50263
Teeth and Rotation 10    CCW
Application AUDI, VOLKSWAGEN
BOSCH Starter ZJS-B-001	CS1330	LRS01675	0-001-120-406 0-001-120-407 02T-903-024R 02Z-903-023C	32675	STR50263	12V/1.0KW	10	CCW	Audi, Volkswagen 
    

   
Item OE Maker BOSCH Starter
Lester No. 32675
Power.: 12V/1.0KW
ZJ No. ZJS-B-001
Hc Parts CS1330
Lucas No. LRS01675
Cargo No.  
OEM  No. 0-001-120-406,0-001-120-407,02T-903-024R,02Z-903-023C
Woodauto No. STR50263
Teeth and Rotation 10    CCW
Application AUDI, VOLKSWAGEN
BOSCH Starter ZJS-B-001	CS1330	LRS01675	0-001-120-406 0-001-120-407 02T-903-024R 02Z-903-023C	32675	STR50263	12V/1.0KW	10	CCW	Audi, Volkswagen 
    

 

Flowmeter

Plastic Flowmeter is a widely used instrument in water treatment engineering, mainly used for flow detection, usually installed after the water pump, to control the water intake of each structure, currently the most widely used are electromagnetic flowmeter and ultrasonic flowmeter. In the selection of the flowmeter, the first thing to consider is the corrosiveness of the measured medium to the flow-passing parts, so as to avoid affecting the service life of the flowmeter due to the corrosion of the medium; During the design and installation process of the flowmeter, the length of the straight pipes before and after the flowmeter needs to be considered. Usually, the principle of 5D before and 3D after the flowmeter is followed. Here, D is the inner diameter of the pipe. If the length is insufficient, the measurement accuracy will be affected. When using an ultrasonic flowmeter, the distance between the first 10D and the rear 5D must be met, and the distance from the flowmeter to the water pump must be more than 30D.

When selecting the type, the flow rate of the medium in the pipeline needs to be between the maximum value and the minimum value of the selected flowmeter, and avoid approaching the maximum or minimum value, so as to avoid affecting the measurement accuracy.

Plastic Flowmeter,Acrylic Flowmeter,Solenoid Valve,Liquid Filled pressure gauge

Hebei Chengda Water Technology Co.,Ltd. , https://www.arclionchengda.com