SZ water ring vacuum pump maintenance methods and quality standards
1 Shell and pump cover 1.1 The shell and pump cover shall not be cracked or large defects such as trachoma, ceramic lining shall not be damaged. This article Keywords Search: More Pumps Technical Articles Pumps Products Offers Home Appliances Injection Molding Parts With many years of industry production experience, we can process and order according to drawings and samples, source manufacturers, quality assurance, complete specifications, high-quality after-sales service, modern complete sets of production equipment and superb workforce, with an annual production capacity of nearly 1,000 tons. Liquid silicone vulcanization molding equipment, injection molding process, extrusion/extrusion, Home Appliances Injection Molding Parts,Household Custom Plastic Injection Molding,Custom Size Plastic Injection Moulding Parts,Plastic Injection Moulding For Home Use Suzhou Dongye Precision Molding Co.,Ltd. , https://www.sjinjectionmolding.com
1.2 Cast iron pump cover and shell end corrosion or erosion serious, can not guarantee the sealing requirements, should be scrapped. If the lining of the ceramic pump cover is damaged, it can be repaired by replacing the liner.
2 Spindle, impeller and sleeve 2.1 spindle should not have corrosion, cracks and other defects.
2.2 Spindle and rolling bearing with H7 / js6 or H7 / k6
2.3 spindle and impeller with H7 / m6.
2.4 Both ends of the impeller and the gap between the front cover and rear cover shall comply with the provisions of Table 5:
The sum of the clearance between the impeller and the pump before and after the cover Sz-1: install the gap 0.30, overhaul gap 0.40, replace the gap 1;
Sz-2: Installation clearance 0.30, Service clearance 0.40, Change clearance 1;
Sz-3: Installation clearance 0.40, Service clearance 0.50, Change clearance 1;
Sz-4: Installation clearance 0.40, Service clearance 0.50, Change clearance 1;
2.5 Spindle straightness should be Φ0.08-0.10mm / m.
2.6 impeller blades should not have burrs and cracks.
2.7 serious impeller corrosion or blade thickness reduced by half, it should be replaced.
2.8 Concentricity of impeller and shaft hole is Φ0.06mm.
2.9 impeller balance test should be done when necessary, its requirements should be consistent with the provisions:
SZ-2: Impeller speed: 1450r / min, Impeller width / Impeller diameter: 220/200 = 1.10, Balance type: Dynamic balance area, Measured on the impeller diameter Allowable deviation Static balance Allowable deviation 5g, Dynamic balance Allow residual amplitude 0.06 ~ 0.08mm
SZ-3: impeller speed: 975r / min, impeller width / impeller diameter: 320/332 = 0.93, balance types: static and dynamic balance area, measured on the impeller diameter tolerances static balance allowable deviation 8g, dynamic balance allowed residual amplitude 0.07 ~ 0.10mm
SZ-4: Impeller speed: 730r / min, Impeller width / Impeller diameter: 520/450 = 1.15, Balance type: Static and dynamic balance area, Measured on the impeller diameter Allowable deviation Static balance Allowable deviation 10g, Dynamic balance Allow residual amplitude 0.07 ~ 0.10mm
2.10 Impeller and shaft assembly, the end of the round beating is 0.10mm.
2.11 sleeve and shaft shall not use the same material, so as not to bite.
2.12 The end face of the shaft perpendicular to the axis is Φ0.01mm.
2.13 Sleeve and shaft contact surface roughness of not more than 1.6, using H7 / h6 with.
3 sealing device 3.1 packing seal 3.1.1 packing gland end face and packing box end face should be parallel, tightness of the fastening bolts should be consistent to avoid bias.
3.1.2 gland into the depth of the stuffing box is generally a circle of filler height, but not less than 5.00mm.
3.1.3 Filler incision should be parallel, neat, not loose, incision 30o angle, the filler should be staggered when the interface 120o.
3.2 mechanical seal 3.2.1 dynamic and static ring surface quality is good, does not allow defects, cracks, radial scratches and other defects.
3.2.2 The seals should be intact, rubber seals should be replaced each time you remove.
3.2.3 spring performance is good, no significant deformation.
4 Rolling bearings 4.1 roller bearings and slide surface should be no scars, spots, smooth contact surface, no noise rotation.
4.2 Rolling bearing outer ring with the bearing should be H7 / h6.
4.3 When mounting the bearing, the rear bearing should be fixed and the front bearing (on the motor side) should have an axial clearance of 0.20-0.30mm.
4.4 hot mounted bearings, with 100-120 ℃ oil and oil bath bearings 10-15 minutes, or heated with electric heaters, non-direct flame heating is strictly prohibited.
5 Flexible Couplings 5.1 Flexible Couplings and Shafts with H7 / js6 or H7 / k6.
5.2 The radial coupling of two halves should not be greater than 0.07-0.09mm. '
5.3 elastic sleeve pin with uranium two-axis deviation and the gap between the end face of the coupling shall comply with the provisions of Table 7
Specializing in the production of medical registration accessories, quality assurance, injection molding products, using exquisite craftsmanship, supporting customization, we require every product to have excellence and tough quality. Why choose us? We have a professional team of engineers and sales teams, most of whom have more than 10 years of experience in the mold industry and injection molding industry, especially in the medical, electronic and automotive industries. We have high-quality equipment machines, such as 4-axis and 5-axis CNC machines, which provide stable and precise machining capabilities.