West Company titanium ore dressing plant production since 1965, sorting beach placer Western Australia, ores containing low Cr 2 O 3 (0.03% to 0.04%) containing TiO 2 54% ~ 60%. The plant uses a re-election, magnetic separation, and electric selection process to select 60 tons of ore per hour. The heavy mineral content of the concentrate is 93% to 95%, and the production is 25 to 35 tons per hour. Heavy mineral mineral composition: titanium 70 to 85% iron ore; 3-5% zircon; monoid stone traces to 4%; trace to 5% rutile; from 1% to 20% iron ore: garnet trace ~15%. In addition, it contains a small amount of tourmaline , cross stone, spinel, biotite and limonite. The plant obtained ilmenite concentrate through two wet selections and two dry selections, and comprehensively recovered rutile, pyrite, zircon, and monazite concentrate. The raw ore is first screened through a cylinder screen with a sieve hole of 0.5 mm. The product is sieved and sieved by a vibrating screen. The 4 mm sieve is discarded. The -4 mm sieve is dewatered and graded by a double-eagle classification box. The coarse part of the box is sieved by a curved screen and an Alice Chalmers (AC) screening machine. The size of the sieved product is less than 0.6 mm, which is sent to the rough selection of the spiral concentrator and the coarse selection of the three sections. Selected, obtained coarse concentrate, a wet selection process is shown in Figure 1.
Vertical type air handling unit
Air flow 1,000m3/h-50,000m3/h,Coil type 4rows/6rows/8rows
AMRTA air handling unit mainly constructed with filter, heat exchanger, fan motor, fan blower and other main components.
Characteristics:
Vertical Type Air Handling Unit Vertical Type Air Handling Unit,Air Handling Unit Size Calculation,Air Handling Unit Catalogue Carrier,Horizontal Vertical Type Air Handling Unit Jinan Amrta Air Conditioning Co.,Ltd , https://www.amrtaac.com
1.Air handing unit applies colorful steel and galvanized panel as its interior and exterior panel. Inner stuff is the high density polyurethane foam,double pillar and tenon structure that ensures the strength of the unit and low air leakage.
2.High efficiency and low resistance nylon filter that reduce the power consumption obviously. Easy cleaning and simple operation; at the same time, higher level panel filter is optional too.
3.Coil applies pure and seamless copper tube and hydrophilic aluminum fin. Copper tube is under 12MPa water pressure expanding that can adapt to all kind of high pressure and no leakage, as well as ensure the lowest contact thermal resistance and highest heat transfer efficiency.
4.All fans in the unit are selected by professional software to ensure the best condition. Minimize the air volume and air pressure loose after meeting with the customer's requirements. Also ensure the good airflow and reduce the air duct noise.